Advantages and equipment:
heating while driving using a mechanical collision sensor which, in the event of an accident, blocks the gas flow by means of a delay of 3.5 g +/- 0.5 g directly acting on the trigger element, this corresponds to the speed of the vehicle in the event of an average vehicle size collisions of approx. 15 to 20 km/h with a fixed obstacle
possibility of use throughout Europe thanks to the use of high pressure hoses for individual countries (not included in the scope of delivery)
cylinder replacement is possible without interrupting work
non-return valve preventing the flow of gas flow during cylinder replacement
a test kit enabling checking the tightness of the liquid gas installation without disassembling the pressure reducer
version with a connection at the HP outlet. (RVS) 10 is standardly equipped with an adapter for connection to 8 mm pipes
Set elements:
automatic switch, low pressure reducer with blow-off safety valve (PRV), mechanical impact sensor, button, reserve indicator, non-return valve, control kit and wall bracket
Technical data:
- output pressure 30 mbar
- efficiency 1.5 kg/h
- horizontal installation
Approval:
- EC - type testing according to GAR